Agilent Technologies E5071C Guide de l'utilisateur Page 202

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 551
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 201
202 Chapter 13
SCPI Command Reference
E5061A/E5062A commands
E5061A/E5062A commands
This section describes the commands specific to the E5061A/E5062A.
:ABOR
Syntax :ABORt
Description Aborts the measurement and changes the trigger sequence for all channels to idle state. (No
query)
After the change to the idle state, the channels for which the continuous initiation mode is
set to ON (set to ON with the :INIT{1-4}:CONT command) change into the initiate state.
For details about the trigger system, refer to “Trigger system” on page 80. (No query)
Example of use
10 OUTPUT 717;":ABOR"
Related commands :INIT{1-4} on page 340
:INIT{1-4}:CONT on page 341
Equivalent key
[Trigger] - Restart
Vue de la page 201
1 2 ... 197 198 199 200 201 202 203 204 205 206 207 ... 550 551

Commentaires sur ces manuels

Vikiehs 04 Jan 2024 | 13:20:06

urenrjrjkvnm