Chapter 13 335
SCPI Command Reference
E5061A/E5062A commands
13. SCPI Command
Reference
:DISP:WIND{1-4}:X:SPAC
Syntax :DISPlay:WINDow{[1]|2|3|4}:X:SPACing {LINear|OBASe}
:DISPlay:WINDow{[1]|2|3|4}:X:SPACing?
Description Selects the display method of the graph horizontal axis of channel 1 (:WIND1) to channel 4
(:WIND4) for segment sweep.
Parameters
Query response {LIN|OBAS}<newline><^END>
Example of use
10 OUTPUT 717;":DISP:WIND1:X:SPAC OBAS"
20 OUTPUT 717;":DISP:WIND1:X:SPAC?"
30 ENTER 717;A$
Related commands :SENS{1-4}:SWE:TYPE on page 428
Equivalent key
[Sweep Setup] - Segment Display
Description
LINear Specifies the frequency base (linear frequency axis with the
minimum frequency at the left edge and the maximum frequency
at the right edge).
OBASe
(preset value)
Specifies the order base (axis in which the measurement point
numbers are positioned evenly in the order of measurement).