
Test 10. Frequency Response Test
Test
10.
Frequency
Response
‘I&t
Step
12
Min Measured Max
Deviation
1
kHz to
100
kHz
1.2 dB
Step 18
Spectrum
Analyzer
START STOP
mQ
F=Q
100
kHz
4 MHz
4
MHz 60 MHz
60
MHz
12.5
GHz
Signal Level
100 Hz
200
Hz
300
Hz
400
Hz
500
Hz
600
Hz
700
Hz
800
Hz
900 Hz
1
kHz
Deviation
100
Hz to 1 kHz
Min
-1.4
dB
-1.4
dB
-1.4
dB
-1.4
dB
-1.4
dB
-1.4
dB
-1.4
dB
-1.4
dB
-1.4
dB
-1.4
dB
Measured
Steps 27, 35 and 49. 100 Hz to 2.5
GHz
Frequency Rand
Frequency
Synthesizer
Freq
Sweep
START STOP
Width
FRRQ
FRRQ
2,000,lOO
Hz
3,998,OOO
Hz
30050
kHz
59900
kHz
-
-
Synthesized
Sweeper
Sweep Time
150 s
60 MHz 2.5
GHz
Max
-2.6
dB
-2.6
dB
-2.6
dB
-2.6
dB
-2.6
dB
-2.6
dB
-2.6
dB
-2.6
dB
-2.6
dB
-2.6
dB
1.2
dB
Trace
Limits
Spec f0.6
dR
Minimum
Maximum
Amp
1
Freq
1
Amp
1
Freq
Performance Tests 2-101
Commentaires sur ces manuels