17.
20130
Loop Phase Lock Adjustments
Note
.Adjustments
AlOA4L16
160 MHz PEAK and
AlOA4L17
160 MHz
PEAK are sealed at the factory and normally do not require
readjustment unless a component failure has occurred. lb verify their
proper adjustment, skip to step 7.
6. Adjust
AlOA4L16
160 MHz PEAK and
AlOA4L17
160 MHz PEAK
to maximize the amplitude of the 160 MHz signal displayed on the
second spectrum analyzer. The two adjustments are interactive;
repeat the adjustment as necessary to ensure maximum signal
amplitude. Refer to Figure 3-80 for the location of
AlOA4L16
160
MHz PEAK and
AlOA4L17
160 MHz PEAK adjustments.
7. Adjust
AlOA4C50
160 MHz PEAK to maximize the amplitude of
the 160 MHz signal displayed on the second spectrum analyzer. If
after adjustment
AlOA4C50
is completely open, select a lower
value for factory-selected component
AlOA4C49;
conversely,
if after adjustment
AlOA4C50
is completely closed, select a
higher
value
for factory-selected component
AlOA4C49.
Refer to
‘Ihble
3-12 for the acceptable range of values and corresponding
HP part numbers for
AlOA4C49,
and to Figure 3-80 for the
location of
AlOA4C50
160 MHz PEAK and
AlOA4C49.
‘Ihble
3-12. Standard Values for AlOA4C49
HP Part Number
0160-3874
0160-4520
0160-4521
0160-4522
0160-4289
8. On the RF Section, key in (CENTER FREQUENCY) 42.450 MHz,
(FREQUENCY SPAN) 100
kHz,
SWEEP
cm),
TRACE A
(CLEARWRITE).
9. Set the controls of the second spectrum analyzer as follows:
CENTER FREQUENCY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.6
MHz
FREQUENCY SPAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 MHz
RES BW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAUTO)
REFERENCE LEVEL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30
dBm
LOG SCALE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 dB/DIV
MARKER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
m
10. On the second spectrum analyzer, press MARKER (PEAK SEARCH) to
position the marker on the peak response. If this level is not at
least -42
dBm,
repeat steps 3 through 10.
11. Disconnect the second spectrum analyzer from SMB test
connector
AlOA4J4.
Connect the second spectrum analyzer to
AlOA4J2
OUT 160
-
166 MHz. Connect the DVM to
AlOA4TP3.
Refer to Figure 3-80 for the location of
AlOA4TP3.
Adjustments
3-l
57